Skip to content

FAQs

Questions about TM65 and Bill of Impact

What TM65 is and when it is used instead of an EPD, the data a report needs, and how hosting and access work.

TM65 and EPDs

What is CIBSE TM65?

TM65 is a calculation methodology published by CIBSE, the Chartered Institution of Building Services Engineers, for estimating the embodied carbon of building services equipment: chillers, air handling units, fan coils, pumps, heat interface units and similar products.

It needs a modest set of inputs from the manufacturer and fills the remaining gaps with published reference values, so a product can be given a reasonable embodied carbon figure without a full life-cycle assessment.

When is TM65 used instead of an EPD?

An Environmental Product Declaration (EPD) is the most robust source of embodied carbon data: a full life-cycle assessment to EN 15804, verified by a third party. Many HVAC products do not have one yet, because an EPD takes considerable time and cost for each product.

Building services engineers and embodied carbon assessors use a TM65 figure when no EPD exists for the product they are specifying. Manufacturers are therefore asked for TM65 calculations, often for a whole range at once.

Does a TM65 report replace an EPD?

No. A TM65 result is an estimate with a buffer factor added for uncertainty, and it is not third-party verified. It is the accepted interim answer while no EPD exists. If your clients need verified data, an EPD is still the goal; the data you enter here is kept in a form an LCA practitioner can reuse for one.

Will the result match CIBSE's own calculator?

With the same inputs and no extra data, yes: the calculation follows the TM65 methodology and was checked against a worked example from CIBSE's calculator, stage by stage.

Where you have better data than TM65's defaults, such as real transport routes, measured energy per unit or how often individual parts are replaced, it is used instead and the report lists each of those deviations with your justification.

Your data

What data does a TM65 report need?

For every product: its weight, product type and material composition, either as percentages by weight or through a bill of materials whose parts each have a composition. At least 95% of the weight must be accounted for; TM65 assigns the rest to steel.

If the product contains refrigerant: the refrigerant, its charge in kilograms and the product's service life.

For a mid-level calculation, also: the factory where it is made, the factory's energy use over a period (electricity, gas and other fuels from your bills) and its output over the same period. Transport routes from suppliers and to markets are optional; without them TM65's default distances are used.

What is the difference between basic and mid-level?

The basic calculation uses material composition (including parts replaced during the product's life) and refrigerant only. It multiplies the materials' embodied carbon by a scale-up factor that stands in for manufacturing, transport and end of life, so it needs the least data.

The mid-level calculation replaces that scale-up with a figure for each stage: transport to the factory, factory energy, transport to site, repair, and end-of-life transport, processing and disposal. It needs factory energy data and reflects how and where your product is actually made. Both add a buffer factor for uncertainty, and you can calculate either for the same product.

How do refrigerants affect the result?

For products with refrigerant, leakage often outweighs everything else. TM65 counts the refrigerant expected to leak over the product's life (charge × annual leak rate × global warming potential × years of service) and the share not recovered at end of life.

Leak and recovery rates come from TM65's scenarios unless you have evidence for your own, in which case you can override them with a note that appears in the report. The buffer factor is not applied to refrigerant leakage.

Can I import data from spreadsheets or our ERP system?

Yes. Vendors, your bill-of-materials catalogue and product BOM lines can be imported from .xlsx, .xls or .csv files up to 10 MB. You match the file's columns to our fields, review exactly what will be created, updated or rejected, and then commit. Nothing is written until you do, and the mapping is offered again next time.

Everything can also be entered and corrected by hand.

What happens when some data is missing?

Nothing is guessed. Before you calculate, a checklist names each missing input and links to where it is entered. A report cannot be issued while a required input is missing, and every place where a TM65 default is used instead of your own data is shown as such.

What does an issued report contain?

Product information as CIBSE's reporting form lists it, the result by life-cycle stage with and without the buffer, refrigerant leakage, the assumptions and sources used, deviations from TM65 defaults with your notes, and appendices with the material, energy and transport detail.

Each report has its own number and a PDF, and it keeps a frozen copy of the inputs and reference values it was calculated from, so later edits never change an issued report. A report is never edited; it can be withdrawn with a reason and stays readable.

Accounts, hosting and service

Where is my data hosted?

In the European Union, in Frankfurt, Germany. The application, its database and its file storage all run in Frankfurt data centres.

How do I get an account, and how does sign-in work?

Access is by invitation only; there is no public sign-up. We set up your organisation and its first user, who then invites colleagues as owners, admins, members or viewers.

There are no passwords. You sign in with a six-digit code sent to your email address; each code works once and expires after five minutes.

Who can see my organisation's data?

The people in your organisation, according to their role, and our own support team, who need access to help you prepare and check your data. Other organisations never see your data.

Is consulting support included?

Yes. Collecting embodied carbon data for the first time raises questions, so help from our team with gathering, structuring and checking your data is part of the service, not an extra.

What is planned next?

Environmental Product Declarations and Digital Product Passports. Neither is available yet. The data model already keeps your inputs (materials, suppliers, transport, energy, refrigerant) separate from TM65-specific results, so that the same data can later be handed to an LCA practitioner for an EPD without asking you again.

How much does it cost?

It depends on the number of products and the support you need, so we quote for each organisation. Send us a short description of your product range through the contact form.

Another question, or ready for a quotation?

Contact Us